Energetics
Energetic, Energy, Automation, Lighting, Reactive Energy, Occupational Safety, Fire Protection, Design and Supervision of Power Systems
Energetic, Energy, Automation, Lighting, Reactive Energy, Occupational Safety, Fire Protection, Design and Supervision of Power Systems
136
page-template,page-template-full_width,page-template-full_width-php,page,page-id-136,bridge-core-2.5.3,ajax_fade,page_not_loaded,,qode_grid_1300,footer_responsive_adv,qode-content-sidebar-responsive,qode-theme-ver-23.8,qode-theme-bridge,wpb-js-composer js-comp-ver-6.4.1,vc_responsive,elementor-default,elementor-kit-817
 

Energetics

It is Energy that start a World

No matter the industry, infrastructure or buildings. Every environment depends on the safe delivery of electricity. We offer you a wide range of power stations and distribution systems.

– Designing

– Construction works

– Audits and testing of electrical installations

– Diagnostic tests of transformer cells

– Audit and testing of power plants

– Designing

– Implementations

– Designing

– Implementations

– Designing

– Implementations

 ENERGETICS

Energetics – Design

– Design of electrical installations in residential and industrial buildings
– Design of power distribution networks of voltage level up to 35kV
– Design of transformer stations
– Designing public lighting
– Review of technical documentation

Energetics – implementations

– Installation and overhaul of electrical equipment
– Perform electrical installations in residential and industrial buildings
– Performance of power distribution networks of voltage level up to 35kV
– Perform transformer stations
– Performing public lighting
– Defects and overhaul of power transformers in operation (in the field) 10-35 kV
– Installation and overhaul of the switch: 6-35 kV low voltage, SF6-45 kV, vacuum 6-35 kV
– Workshop overhaul of distribution transformers 6-35 kV, power 30-2500 kVA,
– Defects, installation and reconstruction of transformers, switches, disconnectors, ducts, collectors, grounding and system of protection against atmospheric discharges of SN installations 6-35 kV,
– Installation of distribution cabinets, installation and installation of cells (air-insulated metal protected switching apparatus),
– Installation and repair of low-voltage SF6 switches, power transformers and other equipment of high-voltage power plants (up to 35 kV).
– Production, construction and reconstruction of electrical installations, devices and installations of mining facilities.
– Production of photoelectric power plants
– Production of distribution cabinets in industry and housing construction
– Supervision of the execution of works

Energetics – Audits and testing of electrical installations

– Testing the continuity of the protective, main conductor of water and conductors for equipotential bonding, testing the galvanic connection of metal masses (exposed conductive parts) with the earthing,
– Inspection and testing of protection by automatic power cut-out (measurement of the impedance of the loop fault, measuring the voltage of the contact, checking the action of ZUDS (current protective switches), voltage protective switches, determining the expected short-circuit current and contact voltage)
– Inspection and testing of safety low voltage protection (“SELV”), ground-level low-voltage grounding (“PELV”) and low operating voltage (“FELV”),
– Testing of insulation control devices (“IT system”),
– Measurement of earth resistance, resistance of distribution and specific resistance of soil,
– Measurement of voltage, current, active, reactive and apparent power of energy, frequency, power factor (cos φ), peak harmonics analysis and phase sequence determination,
– Analysis of the quality of electricity – monitoring of consumption characteristics (measuring and storing the results of measuring the power factor of active, reactive and apparent power and energy, analysis of higher harmonics – harmonic distortion, analysis of voltage decay, shock, power failure and flicker)
– Measurement of insulation resistance (energy cables and conductors) of electrical installations, measurement of electrical resistance of walls and floors,
– Measurement of the electrostatic field,
– Measurement of drainage current (leakage, dissipation),
– Locating the cable trace and determining the fault location on the cables,
– Measurement of the illumination of the interior and exterior lighting,
– Testing of control, signaling, measuring and protection devices,
– Testing of thermal protection of electric motors,
– Inspections, functional measurements and testing of installations and associated devices on facilities,
– Testing of atmospheric discharge protection (lightning rods, etc.)

Energetics – Diagnostic tests of transformer cells

– Measurement of power transformers,
– Measurement of CN switch parameters (transient resistance, switch-on and switch-off times, travel time curves, pole synchronization),
– Measurement of resistance of substation grounding,
– Testing the time of operation and correctness of different types of relays,
– Inspection and testing of VN busbars, insulators and cable connections,
– Response testing for the shutdown of the gas relay and cont. Transformer Thermometer,
– Measurement of the resistance of the spread, the contact voltage and the step voltage,
– Measurement of the noise of the transformer.

Energetics – Audit and testing of power plants

– General inspection and revision of the plant (protective equipment, protective insulation and fire protection equipment, diagrams, phase and polarity approvals), measurement of the resistance of insulation of electrical appliances (power cables, transformers, generators),
– Locating the cable trace, locating cable faults and testing the cables before releasing them,
– Primary and secondary testing of relay protection,
-Insure of relay protection of the transmission line (overhead, directed over-current, thermal and directional earth fault)
– Test relay protection of generators (overcurrent, thermal, differential protection against loss of ignition, protection against asymmetric load, undervoltage and overvoltage),
– Test of relay protection of transformers (overcurrent, thermal and differential),
– Transformer tests when commissioning and auditing,
– Thermographic recording (recording of hot spots on and in devices, machines and equipment, connecting and contact points),
– Measurement of step voltage, contact voltage and ground potential measurement,
– Measurement of ground resistance (operating and protective),
– Checking the galvanic connection on the grounding system,
– Dielectric strength testing of insulating oils,
Testing of switches, switches, disconnectors and earth faults (transient contact resistance, state of isolation and arc protection means, isolation resistance, switch-on and shut-off time, operation of the drive mechanism),
– Testing of protective electrical insulation equipment (electrical insulation rugs, footwear, gloves, poles, detectors (voltage indicators) 1-35 kV voltage, benches, fuse pliers, bulkheads etc.)
– Measurement of noise and vibration,
– Testing and putting into operation of the rectifier.

 ENERGY EFFICIENCY

Energy efficiency – Design

– Design of a system for saving active energy in industry
– Project for KNX INSTALLATION (SMART ROOM)
– Design of peak load management system in industry
– Design of the reactive energy compensation plant
– Design of ultrafast plants for compensation of reactive energy

Energy efficiency – Implementations

– Implementation of a reactive energy compensation plant
– Implementation of peak load management system in industry
– Implementation of an active energy saving system in industry
– Performing KNX installations (SMART ROOM)
– Implementation of ultra-fast reactive energy compensation plants

 TELECOMMUNICATIONS

Telecommunication – Design

– Design of telecommunication networks
– Design of computer networks
– Review of technical documentation

Telecommunication – Implementations

– Implementation of telecommunication networks
– Implementation of computer networks

 Safety technologies

Safety technology – Design 

– Designing a fire protection and fire alarm system
– Design of anti-burglary systems
– Design of the video surveillance system
– Designing a flood notification system
– Review of technical documentation

Safety technology – Implementations

– Implementation of a fire protection and fire alarm system
– Implementation of anti-burglary systems
– Implementation of the video surveillance system
– Installation of a flood warning system
– Installation of access control systems